Notes
This driver takes input from any RH/Temp sensor and calculates Wet Bulb, Dew point, Absolute humidity and several other data points in real time. Optionally it also accepts barometric pressure to accurately calculate Air density.
Registers 9
| # | Name | Unit | Description |
|---|---|---|---|
| 1 | Dry bulb temperature | °C | |
| 2 | Relative Humidity | % | |
| 3 | Air pressure | Pa | |
| 4 | Wet bulb temperature | °C | |
| 5 | Dew point temperature | °C | |
| 6 | Saturation vapor pressure | Pa | |
| 7 | Absolute humidity | g/m³ | |
| 8 | Actual vapor pressure | Pa | |
| 9 | Air density | kg/m³ |